The LTV 1200 Ventilator is specifically designed for the dynamic environment of portable ventilation, whether in-home care, intra-hospital transport or emergency care settings. With its unique combination of features, the LTV 1200 provides clinicians with the flexibility to treat a wide range of patients, from neonatal to adult. The LTV 1200 is the only ventilator on the market that offers both invasive and non-invasive ventilation modes in a single device. This allows clinicians to treat patients with a wide range of respiratory conditions, including COPD, pneumonia, bronchiolitis and asthma. The LTV 1200 also features a built-in oxygen concentrator, which provides a continuous supply of oxygen to the patient, even in the event of a power outage.

The Vyaire LTV 1200 is a portable ventilator that can be used in-home, intra-hospital transport, or in emergency infield use. It is equipped with preset buttons for infants, pediatrics, and adult patients, and can be customized to meet the needs of each individual patient. The LTV 1200 offers both invasive and non-invasive modes of ventilation, including Pressure Control, Pressure Support, Volume Control, and Spontaneous Breath Types. Additionally, the Vyaire Turbine technology eliminates the need for a high-pressure air source, making the LTV 1200 an ideal choice for a variety of medical settings.

 

Vyaire LTV 1200 Ventilator Specifications

Height: 3.25 In (8.4 cm)
Width: 10.5 In (27 cm)
Depth: 13.5 In (38 cm)
Weight: 14.5 lbs (6.5 kg)

Power

Ventilator input 11–15 VDC
AC adapter input 100–250 VAC
50–60 Hz

Pneumatic

High pressure O2 source 40–80 PSIG (2.8–5.5 bar)
Low pressure O2 source < 80 LPM, < 10 PSIG

Controls

Ventilation Modes: Control, Assist/Control, SIMV/CPAP and NPPV
Breath Types: VC, PC, PS and spontaneous
Breath Rate: 0–80 BPM
Tidal Volume: 50–2,000 mL
Inspiratory Time: 0.3–9.9 sec
PC/PS/Spontaneous Flow: 160 LPM
Pressure Control: 1–99 cmH2O
Pressure Support: 1–60 cmH2O
Sensitivity: Off, 1–9 LPM
O2%: 21–100%
O2 flush: 1–3 min
Low pressure O2: On/Off
PEEP/CPAP: 0–20 cmH2O
Insp/Exp hold: 6 seconds maximum
Manual breath: 1x current settings

Monitors and Controls

Peak Inspiratory Pressure: 0–120 cmH2O
Mean Airway Pressure: 0–99 cmH2O
PEEP: 0–99 cmH2O
Breath Rate: 0–250 BPM
Airway Pressure Display: -10–108 cmH2O
Exhaled Tidal Volume: 0–4,000 mL
Exhaled Minute Volume: 0–99.9 L
I:E Ratio: 99:1–1:99
Calculated Peak Flow: 10–100 LPM
AutoPEEP: 0–100 cmH2O
Static Compliance: 1–999 mL/cmH2O
Patient Effort: Green LED

Extended Features

SBT
Ventilator presets (infant, pediatric and adult)
Variable rise time
Variable flow termination
Variable time termination
Pressure control flow termination
Leak compensation
O2 conserve
O2 cylinder duration calculation
O2 flush
Apnea interval

Fixed Alarms

Disconnect/Sense
External power low and lost
High and low O2 inlet pressure
Internal battery low and empty
Ventilator inoperative